Long rod post composite insulator

1. Good electrical specification and strong mechanical strength. 2. Excellent anti-pollution behaviour. Pollution flashover voltage of composite insulators is 2-3 times of that of porcelain insulators. So this product is particularly applicable in the polluted area.

keyword:

Products Details

Long rod post composite insulator
Serial No. Item No. Rating  Voltage  Minimum mechanical failure load kN Creepage distance(mm) Main dimensions Full lightning impulse withstand voltage(kV) 1min Power frequency wet withstand voltage(kV) Manual power frequency withstand voltage≥kV Minimum mechanical torsional load kN
Structure Height(mm) Shed skirt Diameter D(mm) Minimum arc distance(mm) Ash Density 1mg/cm2 Ash Density 2mg/cm2
bend Low temperature bending stretch Low temperature drawing Dry Wet Salt density 0.1mg/cm2 Salt density 0.35mg/cm2
1 FQZ27.5/16-1600 27.5 16 14.4 80 72 ≥1600 690 ≤200 ≥520 310 190 150 45.7  36.0 
2 FQZ27.5/20-1600 27.5 20 18 ≥1600 690 ≥520 310 190 150 45.7  36.0 

 

Product Feature:

1. Good electrical specification and strong mechanical strength.
2. Excellent anti-pollution behaviour. Pollution flashover voltage of composite insulators is 2-3 times of that of porcelain insulators. So this product is particularly applicable in the polluted area.
3. No cleaning and maintenance is required. The unique hydrophobicity and hydrophobicity transfer of the silicone rubber material makes the composite insulator still has excellent hydrophobicity and high pollution flashover voltage after accumulation of pollution, especially suitable for lines with difficult operation and maintenance.
4. The weight is light. It is just 1/7-1/10 of the porcelain insulators. it is very convenient to transport and install. Therefore, it is particularly applicable to the area where the transportation condition is difficult and faulty line's fast emergency repair.
5. The shed has favorable waterproof performance and good anti-ageing.
6. Strong resistance to impact and quakeproof performance.

Product Material:

1. Shed and housing:HTV silicone rubber which hydrophobicity can reach to HC1 level
2.Hot dip Galvanizing steel fitting ,the thickness of the zinc more than 100 μm
3. ECR rod as the core which is high acid resistant. 7200Hr testing passed

Inquiry Now

Complete the form to get more information soon

Welcome to leave your information to get contact with us!

%{tishi_zhanwei}%

Add

Jikai Electric Power Technology Industrial Park,Baoding City, Hebei Province, China.

Share our website


Copyright © 2022  Baoding Jikai Power Equipment Co., Ltd.  All Rights Reserved.  

Business license